1. Prerequisites
Before starting the setup, ensure you have the following:
Bosch Panel
USB Cable
Ethernet Cable (if using network connection)
Transformer and Battery (for power supply)
Remote Programming Software (RPS) installed on a computer
Installation Steps
1. Powering the Panel
Connect the Transformer and Battery to the panel.
Ensure the power supply is stable before proceeding.
2. Network Connection
If using Ethernet, connect an Ethernet cable from the panel to the network.
Ensure the panel and computer running RPS are on the same network.
3. Installing & Logging into Remote Programming Software (RPS)
RPS Installation
Install Remote Programming Software (RPS) on a computer connected to the same network as the panel.
Open RPS and enter the following credentials when prompted:
4. Panel Configuration
For Existing System with Configuration Data
Power up the panel.
Connect to the Panel (via USB or Network).
In RPS, click Receive Data to import the existing panel configuration.
If needed, update the panel’s IP address before importing data.
For Fresh Setup (New Installation)
4.1 Creating a New Panel in RPS
Open RPS and click Create New Panel.
Select a Panel Group.
Enter Panel Name & Description and complete the installation process.
4.2 Open Panel View
In RPS, navigate to View > Panel List.
Right-click the newly created panel and select Open Panel View.
4.3 Configure On-Board Ethernet (IP) Communicator
Set the IP Address, gateway and port number.
Port Configuration
TCP Port: Set to 7700 (recommended) — This port is required for on-premises communication between the Genea Gateway and the Bosch Panel. No external traffic routing is necessary.
Firewall Rules:
Allow all outbound connection on Port 8883 (MQTT over TLS) Ensures secure communication over the internet.
Use this configured IP address in the Genea application when creating the controller.
4.4 Configure Automation Passcode
Set the Automation Passcode in RPS.
Use this passcode in the Genea application when creating the controller.
4.5 Miscellaneous Settings
Set Time Zone & Time Format.
Enable Tamper Detection:
5. Connecting the Panel to RPS
Via USB Cable
Insert one end of the USB cable into the panel.
Insert the other end into your computer.
Open RPS and click Connect.
Enter the password obtained from the panel (highlighted in yellow on the panel screen).
Via Network Connection (Alternative)
Ensure the panel’s IP address is correctly configured.
The panel and computer should be on the same network.
Open RPS and click Connect.
6. Sending or Receiving Data
For Existing System
In RPS, click Receive Data to import the existing configuration.
For Fresh Setup
In RPS, click Send Data to upload the initial configuration to the panel.
7. Wiring Connections
7.1 Connecting a Motion Sensor to a B Series Panel
Motion Sensor Terminal | Bosch Panel Connection |
— | COM |
+ | AUX/PWR |
NC | Input Point Number (1,2,3,4,5,6,7,8) |
NC | Register |
T | Register |
T | Input COM |
7.2 Connecting B208 Input Module to Panel
(Follow manufacturer guidelines for wiring connections.)
7.3 Connecting B901 Door Controller to Panel
(Follow manufacturer guidelines for wiring connections.)
7.4 Connecting a REX Sensor to a B208 Input Module
REX Sensor Terminal | B208 Connection |
— | COM |
+ | AUX/PWR |
NC | Input Point Number (1,2,3,4,5,6,7,8) |
NC | Register |
T | Register |
T | Input COM |