Reader Interface Module (SIO)
The Keri Reader Interface Module (RIM) connects Wiegand readers to the NXT controller via the RM3 module.
Configuring NXT RM3 for a Wiegand Reader
Reference Document: Configure NXT RM3 for Wiegand Reader
Step 1: Enter Programming Mode
Press and hold both buttons (SW1 & SW2) on the RM3 module for about 2 seconds.
All 7 LEDs will flash 3 times.
Release the buttons — the module is now in configuration mode.
Button Functions in Programming Mode:
SW1: Scroll through options
SW2: Select the highlighted option
Step 2: Select Reader Type
Supported reader types:
D4: Keri MS Reader (default)
D5: Wiegand Reader
D6: Keri Keypad Reader
D7: Wiegand Keypad Combo
Steps:
Press SW1 repeatedly until the D5 LED lights up for Wiegand.
Press SW2 to select it.
If you selected D5, continue to Step 3 to configure the LED Control Mode.
Step 3: Choose LED Line Control Mode
The default mode is Dual-line (used for Keri Keypad readers).
For Wiegand readers, choose the appropriate Single-Line or Dual-Line LED mode.
Steps:
Press SW1 to scroll through LED control options.
When the correct LED mode is lit, press SW2 to select it.
Press SW2 two more times to save the settings and reboot the module.
⚠️ Do not remove power during reboot. The process takes approximately 10 seconds, and the LEDs will flash as the module resets.
Wiring Reference
Reader Type: D5 Wiegand
LED Control: Single-Line LED (D3)
Wiring: Connect the Wiegand reader to the RM3 interface module.
Reference Diagram: Wiegand Reader Wiring Diagram (Single-Line LED)
REX and Door Switch Mapping
The following is how the inputs and outputs map based on which port the reader is connected to. Note that these do not change between the 2D and 4D version of controller.
Port Number | REX - Input # | Door Switch - Input # | Strike - Output # |
1 | 0 | 4 | 0 |
2 | 1 | 5 | 1 |
3 | 2 | 6 | 2 |
4 | 3 | 7 | 3 |
NXT Controller Configurations
NXT-2D MSC Controller
Designed with two ports.
Genea input numbers are indicated in red on reference diagrams.
Door configuration on Genea dashboard:
Wiring Reference:
NXT-4D MSC Controller
Designed with four ports.
NOTES:
Keri SIO Module
Keri controllers do not support simultaneous use of the internal reader port and an external SIO interface.
If a door is connected to the internal port, SIO configuration must be prevented.
To use SIO:
Remove the existing door from the internal port.
Reset and resync the controller.
Add the new interface panel.
Genea Cloud validates this automatically when creating a new Interface Panel.
Description | Communication Address |
NXT Reader | 1 |
LIOX | 2 |
Weigand Reader | 3 |
Keri Reader | 4 |
ABA Reader | 5 |
Weigand Combo | 6 |
LED Drive Mode Configuration
For OSDP readers on the Keri Controller Internal Interface Panel, the LED Drive Mode functions as expected.
For Wiegand readers connected via RM3: